[Buck manual] Missing description of data in the examples
Chapter 4 of the buck manual (v1.1.0) describes how to run experiments and plot the transient data. But no explanation about the data structure is given. From the examples, it is possible to infer that index 7 and 3 of the data array are the reference and output voltage, respectively. But no description of the other indices are given.
The list of the signals, according to the initialization code, is:
- Inductor current
- Input voltage
- Input dc link voltage
- Output dc link voltage
- Output voltage
- Duty cycle
- Load switch
- Voltage reference